The LegioBox C2 is a universal wireless data logger and M2M gateway
Using the Legiobox C2, every process, machine, or building can be easily monitored. Recording and saving measurement data is done completely automatically. The measurements or events are sent periodically using an internal quad band modem via GSM/GPRS technology.
Should there be any alerts or limit value exceedings, these will immediately be reported to the central data center, where the Avision software is available for you. Avision provides you with a complete online emergency room and control room through the internet, enabling you to send SMS, e-mail or semascript, and generate and distribute automatic reports.
The LegioBox C2 is a universal data logger in a robust aluminum casing. The universal and complete input configuration offers a suitable solution for every situation. The serial port can be used in M2M applications or for IO extensions, while the optional GPS receiver and tilt sensor allow for easy tracking and tracing. The possibility of battery power makes it the ideal logger, even for locations where energy is unavailable.
Unique product features
Default built-in quad band GSM/GPRS modem Completely programmable and configurable through the internet Seven universal analog inputs, voltage, current or RTD One relay output and four digital outputs Low-power possibilities, battery or AC powered Battery-powered, autonomy of up to 10 years Internal step-up switch for external sensors power supply Serial RS485 port for IO expansion or M2M applications Extendable up to 256 in- and outputs using additional IO modules Robust aluminum version The following options are available:
- GPS receiver and tilt sensor
- Internal 90 to 260 Volts power supply with a UPS
- Implementation of your own serial protocol
|
IO specification |
LegioBox C2 |
|
Input 125mV,250mV,500mV,1V,2,5V,5V,10V,0-20mA,RTD (universal, 13/14 Bits) |
7 |
|
Non galvanic separated inputs, open collector or dry contacts (Max. 25 Hz) |
4 |
|
Bi-stable Relay digital output (24 Volt, max. 1 A) |
1 |
|
Sensor power, powered by the data logger (consult Avic for more options) |
12 Volt, 100mA |
|
RS485 interface (standard with Modbus), 2 wire (no galvanic separation) |
1 |
|
I2C (no galvanic separation) |
1 |
|
GPS receiver, MTK chipset, 32 channel |
Optional |
|
Vibration sensor, Omni directional |
Optional |
|
Maximum inputs and outputs (tags) |
256 |
|
Energy |
LegioBox C2 |
|
Power supply. There are many different operating modes
please contact Avic distributor or Avic solution provider for details
(The optional Main Power supply for the LegioBox C2 also contains an UPS) |
1xD cell Lithium
Or: 12-24VDC
Or: 100-230V AC |
|
UPS 8,2 Volt (250mAh) |
Optional |
|
Base load without any actions (low power operation) |
95µA |
|
Base load without any actions (normal, continuous operation) |
100mA |
|
Power consumption during sampling (low power, without sensor power) |
5mA |
|
Power consumption during data transmission (GPRS) |
260mA |
|
Energy consumption all values depends highly on usage and are indicative |
|
|
5 min. sampling interval, transmission every day (low power) |
1mWatt |
|
Unit is always on and connected (standard power) |
2,6 Ah per day |
|
Estimation of the Battery life (assumption every 15 minutes a sample, daily communication) |
3-5 years |
|
Casing & mounting |
LegioBox C2 |
|
Aluminium casing (IP67) |
Yes |
|
Size in mm (H x W x D) |
60x160x90 |
|
Weight (depends on execution) |
0,7 kg |
|
Mounting method |
Screw 4x |
|
Environment (-20ºC / +50ºC) |
IP65 / IP67 |
|
Number of External cable glands |
5 x PG9 |
|
Internal screw terminals, max.1,5mm2 |
To connect main supply |
|
Internal cage Clamp terminals, 1,5mm2 |
Yes |
|
Software options |
LegioBox C2 |
|
Real time clock (automatically synchronised) |
Yes |
|
Modbus RTU (standard RS232 /RS485, other interface are possible) |
RS485 |
|
GPS |
Optional |
|
Custom serial protocols (RS232 / RS485 / I2C > Custom implementation by Avic BV) |
Optional |
|
Formulas + local programming (PLC alike) |
Yes |
|
Memory (estimation of samples you can store) |
>120.000 |
|
Low power features |
Yes |
|
Standard(S) Smart Sampling(SS), High Speed Sampling(HS), Conditional Sampling(CS) |
S, SS, HS, CS |
|
Programmable delay, timers, filters, alarm thresholds and Hysteresis |
Yes |
|
Communication |
LegioBox C2 |
|
GPRS / GSM Quad band modem |
Standard |
|
Applications
Telemetry and data logging - Pressures, water level or overflow
- Temperatures
- Flow, Pulses
- Gasses
- Sound
- Vibrations and subsidences
E-metering
- Power consumption
- Gas consumption
- Water consumption
- Heat consumption
Monitoring of:
- Data centers and computer rooms
- Quality of water and air
- Buildings, shops, and schools
- Refrigerators, cold- and frozen food stores
- Industrial processes and machines
Tracing & Tracking - tracking of vehicles
- monitoring of mobile equipment
M2M (Machine to Machine)
Markets
- Water world, environment, waste disposal
- Industry, energy, chemistry, nutrition
- Utility, buildings and schools
- Healthcare and pharmacy
|